Chembio CTP Dev 92 works reliably with a wide range of plates. The operating parameters of the developer are presented in the table below.
The described parameters for working with the Chembyo CTP Dev developer are not specific recommendations. The provided information is based on the analysis of our clients’ experience with this product. The table indicates the operating parameters after the fresh product is added. During operation, depending on the type and quantity of plates, the parameters (developer temperature and plate development speed) will change. This is, of course, a normal occurrence for these processes.
Equipment | Plate type | Exposure power | Exposure speed | Developer temperature | Plate development speed. | Replenishment | Developer lifespan |
Fuji Luxel t9000 | Prima UV | 95% | 900 rpm. | 23 градуси | 30-40 s. | 100 ml | 1500 м2 |
Prima ECO | 700 rpm. | 23 degrees. | 60-70 s. | 100 ml | |||
DTP-II | 700 rpm. | 23 degrees. | 40-50 s. | 100 ml | |||
NEXT | 700 rpm. | 24 degrees. | 50-60 s. | 100 ml | |||
Smart | 650 rpm. | 25 degrees. | 70-80 s. | 100 ml | |||
Glunz – 85 | DTP-II | 95% | 800 rpm. | 24 degrees. | 40-50 s. | 100 ml | 1 month |
Kodak | FujiPCE, | 90% | 800 rpm. | 23 degrees. | 50-60 s. | 100 ml | 1 month |
Huaguang | 95% | 800 rpm. | 23 degrees. | 50-60 s. | 100 ml | 1 місяць | |
Glunz 85 HD | DTP2 | 95% | 700 rpm. | 24 degrees. | 40-50 s. | 100 ml | 1,5 month |
Vela | 95% | 900 rpm. | 24 degrees. | 40-50 s. | 100 ml | ||
Ovit – 85 | Huaguang | 90% | 700 rpm. | 23 degrees. | 40-50 s. | 100 ml | 2 months |
Glunz – 135 | Smart | 95% | 700 rpm. | 24 degrees. | 50-60 s. | 100 ml | 1 month |
FujiPCE | 95% | 900 rpm. | 23 degrees. | 40-50 s. | 100 ml | ||
FujiPYE | 90% | 900 rpm. | 23 degrees. | 40-50 s. | 100 ml | ||
KodakXD | 90% | 900 rpm. | 23 degrees. | 40-50 s. | 100 ml | ||
Raptor | Dtp-2 | 95% | 700 rpm. | 23 degrees. | 50-60 s. | 100 ml | 2 months |